Technique Print Samples - page 147

Compressor Section
THRESHOLD1
This control sets the first level at which the compression begins to take
effect.
RATIO1
This control sets the first degree of compression.
THRESHOLD2
This control sets the level at which the second compression ratio will
begin to take effect.
RATIO2
This control sets the compression ratio when the second
Threshold
is
reached.
ATTACK
This control sets the time taken for the
Compressor
to reach full
compression.
HOLD
This control sets the time the
Compressor
will stay at full compression
before starting the
Release
phase.
RELEASE
This control sets the time the
Compressor
takes to return to no
compression after the
Hold Period
has expired.
GAIN
This control compensates for any loss of average signal level within the
Compressor
.
LIGHTMETERS
Two
Lightmeters
appear on the device.
I/P
displays the incoming signal,
G/R
displays the gain reduction being applied.
145