Technique Print Samples - page 143

HOLD
When the
Gate
has been opened and the input signal level has decreased
below the
Threshold
and
Hysteresis
settings, the
Hold
control
determines the length of time the
Gate
stays fully open.
LOG
This switch determines the curve used during the
Release
period. When
selected a logarithmic decay curve is used. Normally the curve is linear.
RELEASE
This control sets the time the
Gate
takes to ramp from open to closed.
MASK
This switch forces the
Mask Period
to pass before the
Gate
can be
re-triggered.
RANGE
This control sets the attenuation applied when the
Gate
is closed.
GAIN
This control sets the overall output gain of the processed signal.
LIGHTMETERS
Two
Lightmeters
appear on the device.
I/P
displays the incoming signal,
G/R
displays the gain reduction being applied.
141
Supertrue 4 User Guide
1...,133,134,135,136,137,138,139,140,141,142 144,145,146,147,148,149,150,151,152,153,...166