Technique Print Samples - page 5

stereo input
O/L
0
-10
-30
G
R
O
U
P
S
+5
+10
0
-5
-20
-30
-10
-15
-40
-50
TALLY
MUTE
PAN
L R
AUX
1+2
PRE
PRE
0
AUX
3+4
0
AUX
5+6
PRE
0
AUX
7+8
PRE
0
EQ
0
dB
LF
3x
40
80
Hz
80
200
500
1k
2k
5k
3x
Q
dB
0
MF
dB
0
HF
6k
12k
GAIN
dB
+20
-20
0
L
R
MONO
M/S
LBS
C
1
PF
ST
1-2
3-4
5-6
7-8
LBS Stereo Input
Balanced Input
Mono Left
Applies the left hand signal to both left and right hand sides of the module.
Mono Right
Applies the right hand signal to both left and right hand sides of the module.
*
If both mono switches are pressed together, a blend of left and right signals appears on
both sides of the module.
Phase Reverse
Reverses the phase of the right hand signal only.
Gain Control
From -20 to +20 dB.
Three Band Equaliser with “IN” switch
HF
+/-18 dB shelving response at a frequency of 6 kHz or 12 kHz.
MF
+/-14 dB with a continuously variable frequency range from 80 Hz to 5 kHz.
The x3 button changes the range to 240 Hz - 15 kHz.
MF Q Switch
Q setting of 0.7 or 1.3
LF
+/-18 dB shelving response at a frequency of 40 Hz or 80 Hz.
The x3 Button changes the frequencies to 120 Hz or 240 Hz.
HP Filter
18 dB per octave, -3dB at 80 Hz.
8 Aux Sends
Mono Aux Sends
Aux sends 3/4, 5/6, and 7/8 are fed from the sum of left and right signals.
They can be switched Pre-Post fader in pairs and have dual concentric controls for level/level
arrangement.
Stereo Aux Send
Aux 1/2 is similar but has an internal option to change the controls to a stereo level/pan
arrangement, i.e. Aux 1 will be fed from the left only and Aux 2 will be fed from the right only.
Other Features
Insert point
The insert point is post-EQ and pre-fader. The insert return is balanced.
Channel Pan
This pans across the stereo and group buses. Pan to left routes to the odd groups and pan to
right routes to the even groups.
Soft Mute
The module uses a soft mute circuit for click free switching.
Fader
Conductive Plastic ALPS 100 mm fader with 10 dB gain in hand.
Fader Start
- is provided
PFL
The PFL switch provides stereo pre-fade signal to the monitor speakers.
AFL Option
An internal jumper option allows the PFL signal to be replaced by AFL - this signal is derived
post pan.
Meter
A four segment meter displays channel pre-fade level, monitoring left and right
simultaneously. The overload lamp lights when the signal reaches +18 dB.
Group Routing
Four Group assign switches are provided, assigning groups in pairs. These are labelled
‘1/2’, ‘3/4’, ‘5/6’, and ‘7/8’.
* Groups are available only if the appropriate number of Group Modules are fitted.
Routing to Stereo
Assigns the signal on the Input module to the Stereo Bus.
1,2,3,4 6,7,8,9,10,11,12,13,14,15,...20
Powered by FlippingBook